Skip to main content
SLAC National Accelerator Laboratory
LCLSLinac Coherent Light Source

User Portal Login   |  LCLS Internal Site

Main navigation

  • About
    • Organizational Chart
    • People & Committees
      • Leadership
      • Users' Executive Committee
      • Scientific Advisory Committee
      • LCLS Detector Advisory Committee
      • Proposal Review Panel
      • SLAC Photon Science Faculty
      • Users' Recognition Award
      • Young Investigator Award
    • Strategic Plan 2023-2028
    • Our Science
    • Internships
      • Intern Testimonials
      • Summer Student Poster Sessions
    • Jobs
    • Multimedia
      • Virtual Tours
      • Fact Sheets & Infographics
      • Image Gallery
      • Youtube Videos
    • Coming to SLAC
    • Contact Us
  • User Resources
    • User Research Administration (URA) Office
    • Schedules
    • Proposals
      • Proposal Preparation Guidelines
      • MeV-UED Proposals
      • Proposal Review Process
      • Run 25 Proposal Call
      • Universal Proposal System (UPS)
      • Submit Proposal
      • Archived Proposal Calls
    • User Agreements
    • Policies
    • Proprietary Research
    • Safety & Training
      • Work Planning & Control
      • LCLS Building Orientation
      • Hutch 6 Non-Permit Confined Space Training
      • Sample Delivery Training
      • Sample Prep Lab Training
    • SLAC User Access Requirements
      • Computer Accounts
      • Data Collection & Analysis (PCDS)
      • DAQ
      • Shipping Equipment & Materials
      • Financial Accounts
    • Links By Category
  • Publications
    • LCLS Publications
    • Search Publications
    • Submit New Publication
    • Archived Publications
  • Instruments
    • chemRIXS
      • Science Goals
      • Experimental Methods
      • Specifications
      • Standard Configurations
      • Publications
    • CXI
      • Experimental Methods
      • Specifications
      • Components
      • Standard Configurations
      • Publications
    • MEC
      • Science Goals
      • Experimental Methods
      • Specifications
      • Diagnostics & Components
      • Standard Configurations
      • Lasers & Beam Delivery
      • Publications
    • MFX
      • Science Goals
      • Experimental Methods
      • Specifications
      • Standard Configurations
      • Publications
    • qRIXS
      • Science Goals
      • Experimental Methods
      • Layout & Specifications
      • Capabilities
    • TMO
      • Science Goals
      • Layout & Specifications
      • Standard Configuration
      • Publications
    • TXI
      • Science Goals
      • Experimental Methods
      • Layout & Specifications
    • XCS
      • Experimental Methods
      • Specifications
      • Components
      • Standard Configurations
      • Operation Modes
      • Publications
    • XPP
      • Science Goals
      • Experimental Methods
      • Specifications
      • Components
      • Standard Configurations
      • Publications
    • MeV-UED
      • Specifications
      • Run 6 Scientific Capabilities
      • Schematics
      • Endstations
      • Proposals
      • Proposal Review Process
      • Schedule
      • Publications
    • LCLS-II-HE
    • DXS
      • Science Goals
      • Experimental Methods
      • Specifications
    • Instrument Maps
    • Standard Configurations
  • Machine
    • Machine Status
    • Machine FAQ (NC Linac)
    • Parameters
    • Schedules
  • Projects
    • LCLS-II
      • Science
      • Design & Performance
      • Commissioning
    • LCLS-II-HE
      • Science
      • Design & Performance
      • Meetings and Reports
      • Instruments
      • Internal Site
    • MEC-U
      • Science Mission
      • Design & Performance
      • Workshops & Meetings
      • Publications
      • News
      • Resources & Photos
      • Internal Site
  • Departments
    • SRD Leadership
    • Atomic, Molecular, & Optical Sciences
      • Research Interests
      • People
      • Research Highlights
      • Attosecond Science Campaign
    • Biological Sciences & Sample Preparations
      • Sample Environment & Delivery
      • Sample Preparation Laboratories
      • Biolabs at the Arrillaga Science Center (ASC)
      • Equipment Inventory
      • Chemical Inventory
    • Chemical Sciences
      • Research Interests
      • People
      • News & Highlights
      • Publications
    • Material Sciences
      • Research Interests
      • People
    • Matter in Extreme Conditions
      • Research Interests
      • People
      • Publications
    • Laser Sciences
      • Research Interests
      • Laser Capabilities​
      • People
      • User Resources
    • Detectors
      • Technologies
      • People
      • User Resources
    • Experiment Data Systems
      • Infrastructure
      • People
      • Projects
      • User Resources
    • Experiment Control Systems
      • Leadership
  • News
    • LCLS Science SLAC News Feed
    • Announcements & Updates
    • External News Features
      • Archive
  • Links

Breadcrumb

  1. Home
  2. Departments
  3. Detectors
  4. …
Facebook Share X Post LinkedIn Share Email Send
  • SRD Leadership
  • Atomic, Molecular, & Optical Sciences
    • Research Interests
    • People
    • Research Highlights
    • Attosecond Science Campaign
  • Biological Sciences & Sample Preparations
    • Sample Environment & Delivery
    • Sample Preparation Laboratories
    • Biolabs at the Arrillaga Science Center (ASC)
    • Equipment Inventory
    • Chemical Inventory
  • Chemical Sciences
    • Research Interests
    • People
    • News & Highlights
    • Publications
  • Material Sciences
    • Research Interests
    • People
  • Matter in Extreme Conditions
    • Research Interests
    • People
    • Publications
  • Laser Sciences
    • Research Interests
    • Laser Capabilities​
    • People
    • User Resources
  • Detectors
    • Technologies
    • People
    • User Resources
  • Experiment Data Systems
    • Infrastructure
    • People
    • Projects
    • User Resources
  • Experiment Control Systems
    • Leadership

Detectors Technologies

  • CSPAD (in CXI)
  • ePix100
  • ePix10k
  • Rayonix MX170 & 340
  • Jungfrau
  • pnCCD

Cornell–SLAC Pixel Array Detector (CSPAD)

The first detector specifically developed for use at LCLS is the Cornell–SLAC Pixel Array Detector (CSPAD). This detector is the result of a collaboration between Cornell University and SLAC National Accelerator Laboratory.

CSPAD camera
CSPAD 2.3 megapixel camera located at the CXI instrument.

The CSPAD 140K, 560K, and 2.3M are used for both soft and hard X-ray applications. In instances where the detector needs to cover a large cross sectional area, the CSPAD 2.3M, with its large active sensor area, may be extremely useful. For further expansion of the active area beyond that provided by the 2.3M, multiple CSPADs can be install and read in-sync to cover a large cross section that cannot be covered by a single detector.  

Camera Specifications

Total Length 
(tubings, connectors included)

14.5 in 
(36.8 cm)

Weight

 2.4 lb (1.09 kg)

Room Temperature Operation 
(nominal range)

5-30 °C

# of Pixels

  • 140K

  • 560K 

  • 2.3M 

Modules Active Area

4 x 4 cm2

Quantum Efficiency vs. Energy Range

See figure

View CSPAD specs sheet

Characteristics & Measured Performance

CSPAD

​High Gain

​Low Gain

​Pixel per ASIC

​194 x 185 ​

​Pixel Size 

​110 μm

​Noise R.M.S

​1000 eV

​3500 eV

​Max Signal (8 keV 
photons equivalent)

​350 keV

​2700 keV

​Frame Rate

​120 ​Hz

​Sensor Thickness

​500 ​μm

Resources

  • CSPAD Troubleshooting Guide (SLAC Login needed)​
  • Hands-on Tutorial: CSPADs: how to operate them, which performance to expect and what kind of features are available (Video1, Video2)
  • CSPAD FAQ - Philip Hart (SLAC) (Video)

Analysis Tools 

  • How to run the offline_ami program:
    • ssh pslogin
    • ssh psana
    • cd /tmp/reg/g/pcds/dist/pds/ami-current/build/ami/bin/x86_64-linux-opt/offline_ami -p 
    • /reg/d/psdm/cxi/cxij5116/
  • LCLS Data Analysis​ 
  • Detector Calibration and Management​
  • CSPAD common mode corrections in hybrid gain mode​

ePix100

Detectors Image
ePix100 Cameras

With a 50 μm pixel size, the SLAC developed ePix100 provides one of the highest resolutions of all the detectors available at LCLS. Used in both soft and hard X-ray applications, multiple ePix detectors can be installed and read in-sync in order to expand the cross section covered by the detectors.

The camera dimensions are 2 x 2 x 11.5 inch (5.1 x 5.1 x 29.2 cm), including tubings and connectors.

View ePix100 specs sheet   View ePix100 Geometry 

Characteristics & Measured Performance

​# of Pixels

​4 x (384 x 352)

​Pixel Size

​50 μm

​Noise r.m.s.

​250 eV

​Max Signal
(8 keV photons equivalent)

​< 100 keV 

​Frame Rate

​120 Hz (or up to 1kHz)

​Sensor Thickness

​500 μm

​Weight

​3.0 lbs

ePix10k

Detectors Image
ePix10k-2M Camera

The ePix10k is the next generation detector that replaces the CSPAD in most hard X-ray experiments.  It has 20% smaller pixels, ~5x lower noise, and 4x higher dynamic range compared to the CSPADs. The ePix10k comes in a small (135k) and large (2M) pixel variant.   

 View ePix10 specs sheet View ePix10 Geometry

Characteristics & Measured Performance

​Pixels

​100 x 100 μm

​Noise r.m.s.

​320 eV

​Max Signal
(8 keV photons equivalent)

​11000  keV

​Frame Rate (Hz)

​120 Hz (or up to 1kHz)

​Sensor thickness

​500 μm

Rayonix MX170 & 340

Detectors Image
Rayonix MX170-HS camera
Detectors Image
Rayonix MX340-HS Camera

The Rayonix MX170-HS and MX340-XFEL are commercial CCDs with high spatial resolution/dynamic range and adjustable on-board binning.  

For extra high resolution applications, the 44um pixel size can accommodate at the cost of readout speed. 

  • Quantum Efficiency: up to 0.8 for 8 keV - 12 keV

Camera Specifications

 

MX170-HS

MX340-XFEL (in MFX)

# of Pixels

3840 x 3840 

7680 x 7680 

Active Area Dimensions

170 x 170 mm2

340 x 340 mm2

Pixel Size

44 µm

44 µm

Electro-Optical Gain

7e-/12keV photons

7e-/12keV photons

Full Well Capacity 

360 ke-/pixel

360 ke-/pixel

Noise

8e-/pixel

8e-/pixel

QE

0.8 (8keV-12keV)

0.8 (8keV-12keV)

Signal Dynamic Range

16-bits

16-bits

On-Chip Binning

Square binning: 1 x 1, 2 x 2, 
3 x 3, 4 x 4, 5 x 5, 6 x 6, 
8 x 8, and 10 x 10 pixel binning

Square binning: 1 x 1, 2 x 2, 
3 x 3, 4 x 4, 5 x 5, 6 x 6, 
8 x 8, and 10 x 10 pixel binning

Frame Rate

Depends on binning 

Depends on binning 

View Rayonix MX170-HS specs sheetView Rayonix MX340-XFEL specs sheet

Jungfrau

Jungfrau camera
Jungfrau camera

The Jungfrau is a fast, large dynamic-range X-ray camera deployed at LCLS for hard to tender X-ray in-air applications since run 15.

The in-air camera dimensions are approximately 38 x 9 x 10 cm3 (38 x 13 x 10 cm3) including connectors and tubing for the 0.5 M (1 M).  

Beginning in Run18, the CSPAD2.3M in the CXI/SC1 chamber will be replaced by the Jungfrau 4M detector, which will allow for higher signal and spatial resolution, as well as a larger dynamic range for hard X-ray experiments.  The detector is made up of 8 modules arranged around a 9mm beamhole.

View Jungfrau specs sheet

Characteristics & Measured Performance

 

Jungfrau 0.5M    ​

Jungfrau 1M   

Jungfrau 4M (in CXI)

# of modules

1

2

8

# of Pixels per Module

1024 x 512

1024 x 512

1024 x 512

Application

Air only

Air only

Vacuum only

​Pixel Size (μm)

75

75

75

​Noise r.m.s. (eV)

180-270

180-270

180-270

​Max Signal (8 keV photons equivalent)

​15,000

15,000

15,000

​Frame Rate (Hz)

​up to 2k

up to 2k

up to 2k

​Sensor Thickness (μm)

​320

320

320

​Weight (kg)

​2-3

​2-3

​2-3

Additional Images

Detectors Image
Detectors Image

 

 

 

Detectors Image

pnCCD

The pnCCD is often used for soft X-ray applications. A 75 μm pixel resolution and a large active sensor area mounted on a servo-motor allows for flexibility in the cross section that it covers. The top and bottom halves of the front pnCCD can move independently (vertically) of each other, allowing each to cover a different kinematic region.

The pnCCD detector is used primarily in the AMO hutch. Two detectors front (upstream) and back (downstream) are available for use. The front detectors are on a servo-motor, allowing for the two vertical halves of the detectors to move in all 3 directions. This allows greater flexibility to users in choosing their kinematic regime of interest.

Camera Specifications

​# of Pixels

​2 x (1024 x 512)

​Pixel Size

75 μm

Max Signal 
(1 keV photons equivalent)

6000 keV 

Gain Range

1/256 to 1

​Frame Rate

​120 hz

More Specifications

  • When installed, the top half of the front pnCCD is approximately 5mm upstream of the bottom half.
  • There are 4 ASICs on either side of a single pnCCD plane (for a total of 8 per plane).
  • Dynamic range as well as Z position w.r.t interaction point may vary depending on in-chamber setup. Top and Bottom planes of front pnCCDs move independently of each other vertically. Back pnCCD does not move.
  • A 300 nm thick polyimide filter is placed in front of the pnCCD to prevent sample debris from accumulating on the sensors.

System Information

  • Cooling: Sumitomo HC-8E Compressor with a CH-104 Coldhead
  • Power: Rohde Schwartz NGPS32 Dual Bipolar Power Source
  • Signal Readout: Keithley 2400 Source Meter, Lakeshore 335 Temperature Controller

Analysis Tools

  • ssh to pslogin.slac.stanford.edu
  • ssh to psana.slac.stanford.edu
  • /reg/g/pcds/dist/pds/ami-current/build/ami/bin/x86_64-linux-opt/offline_ami
LCLS | Linac Coherent Light Source
2575 Sand Hill Road MS103
Menlo Park, CA 94025
  • Facebook
  • Twitter
  • Instagram
  • Flickr
  • Youtube
  • LinkedIn
  • Staff portal
  • Privacy policy
  • Accessibility
  • Vulnerability disclosure
SLAC
  • SLAC home
  • Maps & directions
  • Emergency info
  • Careers

© 2025 SLAC National Accelerator Laboratory is operated by Stanford University for the U.S. Department of Energy Office of Science.

Stanford University U.S. Department of Energy
Top Top
Back to top Back to top